RBS 2102Macro Outdoor RBS
Earth Connection
The RBS is provided with an earth bar for connecting the site earth cable. The
earth bar is located behind the ACCU.
External Alarms
External alarms are connected to the RBS 2102 at the transmission connection
field, see Figure 8 on page 18 and Table 8 on page 18.
6.2 Test Interface
The OMT connector provides an interface for the Operation and Maintenance
Terminal. The OMT provides a graphical user interface (GUI) and is used to
verify that the Installation Database (IDB) is installed and contains the correct
equipment configuration information. The OMT can be used to perform the
following:
Display software version
Create or modify the IDB
Define external alarms
Modify or display O&M parameters
Define PCM interface
Define TMA parameters
Monitor and display fault status
6.3 Operator Interface
The Man Machine Interface (MMI) in the RBS 2102 is comprised of optical
indicators, buttons and switches on units in the cabinet. The information here is
general. For a more detailed description of the indicators, buttons and switches
on the various RUs in the cabinet, see the respective units’ description in this
manual.
Optical Indicators
Several units in the RBS have optical indicators that show the operational
status of the unit. The indicators reflect faults, mode change and operation.
20 (24)
E