User Manual

Table Of Contents
RBS 2101Macro Outdoor
Table 8 Power Consumption
Power consumption
Operation
230 V AC 208 V AC
Normal (operation with
peak load and all time
slots occupied)
1000 W 1000 W
Maximum 2100 W 2100 W
8 Transmission
The RBS 2101 is connected to a transmission interface G.703, type E1
(2 Mbits/s) or T1 (1.5 Mbits/s). For E1 interfaces, 75 coaxial or 120 twisted
pair cables are used. For T1 interfaces, 100 twisted pair cables are used.
9 External Alarms
The RBS 2101 can be connected to a maximum of 8 external alarms via the
EACU in the mounting base.
10 Product Approval
This section describes product approval for Europe and North America.
10.1 Europe
The RBS complies to European Community directive R&TTE 1999/5/EC. This
means that the RBS fulfills legal requirements regarding product safety, EMC
(Electromagnetic Compatibility) and Radio.
The RBS has a CE mark to show compliance to the above.
10.2 North America
The RBS complies to the North American legal requirements regarding product
safety, EMC, (Electromagnetic Compatibility) and Radio.
To show compliance to this the RBS has a Listing mark for product safety and
FCC/IC labels for EMC (Electromagnetic Compatibility) and Radio.
16 (18)
E
N/LZT 720 0219 Uen R2A