6.1 External Connections
External connections provided by the RBS 2101 include the following:
Transmission
Antenna
AC mains
Earth
External alarms
Table 5 External Cable Connectors
Connector
Name
Description
Bus-1 Local bus connector for extension cabinet
Bus-2 Y-link connection for EDGE
sTRUs in extension cabinet
Door Alarm sensor connector for door alarm
Ext.Alarm External alarm connector
Ext.T External temperature sensor alarm connector
G.703–1 Transmission interface port
G.703–2 Transmission interface port
GPS/ESB GPS synchronization or ESB connection for TG
synchronization
RX1 Receiver antenna port 1
RX2 Receiver antenna port 2
TM-48V Transport Module connector for -48 V power connection
TM+24V Transport Module connector for +24 V power connection
TX1 Transmitter antenna port 1
TX2 Transmitter antenna port 2
ESB ESB connection for TG synchronization
6.2 Test Interface
The OMT connector provides an interface for the Operation and Maintenance
Terminal. The OMT provides a graphical user interface (GUI) and is used to
verify that the Installation Database (IDB) is installed and contains the correct
equipment configuration information. The OMT can be used to perform the
following:
13 (18)