User Manual
Table Of Contents
- Contents
- 1 Introduction
- 2 Product Safety Requirements RBS 2000
- 3 Environmental Capabilities
- 3.1 Scope
- 3.2 Terminology
- 3.3 References
- 3.4 Transport -40 C – +70 C
- 3.5 Storage -25 C – +55 C
- 3.6 Handling -40 C – +70 C
- 3.7 Operation Indoor +5 C – +40 C
- 3.8 Operation Outdoor -33 C – +40 C
- 3.9 Operation Outdoor -33 C – +45 C
- 3.10 Operation Outdoor -33 C – +55 C
- 3.11 Operation Mast-Mounted Equipment -33 C – +45 C
- 3.12 Operation Mast-Mounted Equipment -40 C – +55 C
- 4 Climate Protection
- 5 EMC Capabilities
- RBS 2101, Product Description
- RBS 2102, Product Description
- RBS 2103, Product Description
- RBS 2202, Product Description
- RBS 2101, 2102, 2103 & 2202 Radio Configurations
- RBS 2202 Antenna Configurations
- ACCU Description
- BFU Description
- CDU-A Description
- CDU-C Description
- CDU-C+ Description
- CDU-D Description
- DXU Description
- DXU-21 Description
- ECU Description
- PSU -48 V Description
- PSU 230 V Description
- sTRU Single Transceiver Unit Description
- V3 Climate Unit Description
- Glossary
PSU 230 VPower Supply Unit
5.1 Power and Signal Interfaces
This section describes the power and signal interfaces, which consist of the
following:
• Power supply
• Power Control Bus (Opto)
Power
The following power connections are located on the PSU:
• Input supply
• Output power
Characteristics of these interfaces are shown in the tables below.
Table 4 Input Data
Nominal input voltage 200 – 250 V AC
Varia
tion input voltage
180 – 2
75 V AC
Frequency 45–65Hz
Current <5Arms(at180VAC)
Inrush current <6 A peak
Internal 6.3 AAC protection
External 10 A (slow); 6 to 16 A is permissable
Table 5 Output Data
Nominal ouput voltage 24 V DC
Present ouput voltage 27.2 ± 0.1 V DC
Voltage Range +22 – +28 V DC
Output power 700 W
Hold-up time >20 ms
Signal
The signal interface consists of an optical fibre link, called the Power Control
Bus (Opto).
8 (10)
EN/LZT 720 0282 Uen R1A