- 2 Product Safety Requirements RBS 2000
- 3 Environmental Capabilities
- 3.1 Scope
- 3.2 Terminology
- 3.3 References
- 3.4 Transport -40 C – +70 C
- 3.5 Storage -25 C – +55 C
- 3.6 Handling -40 C – +70 C
- 3.7 Operation Indoor +5 C – +40 C
- 3.8 Operation Outdoor -33 C – +40 C
- 3.9 Operation Outdoor -33 C – +45 C
- 3.10 Operation Outdoor -33 C – +55 C
- 3.11 Operation Mast-Mounted Equipment -33 C – +45 C
- 3.12 Operation Mast-Mounted Equipment -40 C – +55 C
- 4 Climate Protection
- 5 EMC Capabilities
- RBS 2101, Product Description
- RBS 2102, Product Description
- RBS 2103, Product Description
- RBS 2202, Product Description
- RBS 2101, 2102, 2103 & 2202 Radio Configurations
- RBS 2202 Antenna Configurations
- ACCU Description
- BFU Description
- CDU-A Description
- CDU-C Description
- CDU-C+ Description
- CDU-D Description
- DXU Description
- DXU-21 Description
- ECU Description
- PSU -48 V Description
- PSU 230 V Description
- sTRU Single Transceiver Unit Description
- V3 Climate Unit Description
- Glossary
RBS 2101, RBS 2102, RBS 2103 and RBS 2202 Hardware Reference Manual
Table 11 Mechanical parameters for outdoor operation
Environmental Parameters Unit Value
Vibration sinus:
displacement
mm
0.6
acceleration m/s
2
2
frequency Hz
2 - 9 9 - 200
Random:
Frequency Hz
5 – 200
ASD m
2
/s
3
0.05
(1)
ASD m
2
/s
3
0.1
(2)
ASD m
2
/s
3
0.2
(3)
Exposure time minutes 30/direc-
tion
Shock: < 100 kg > 100 kg
peak
acceleration
m
2
/s
100 50
(4)
duration
ms
11 18
Page 19
(1) Normal condition
(2) Safe function
(3) Non-destruction
(4) These requirements belong to the Safe function with one exemption: performance of the
RBS shall be verified as ‘‘no loss of calls’’ .
Seismic Exposure
The complete equipped RBS shall be tested for seismic exposure. Deviations
shall be reported.
Safe function during seismic exposure. Deviations shall be reported.
Table 12 Seismic exposure limits for outdoor operation
Test frequency range 1 - 35 Hz
Required Response
Spectrum
RRS
Shape of RRS as IEC fig 3
Number of time scale
histories
1/ testing direction
Duration of time scale
histories
35 s
Number of testing directions
3