User Manual
Table Of Contents
- Contents
- 1 Introduction
- 2 Product Safety Requirements RBS 2000
- 3 Environmental Capabilities
- 3.1 Scope
- 3.2 Terminology
- 3.3 References
- 3.4 Transport -40 C – +70 C
- 3.5 Storage -25 C – +55 C
- 3.6 Handling -40 C – +70 C
- 3.7 Operation Indoor +5 C – +40 C
- 3.8 Operation Outdoor -33 C – +40 C
- 3.9 Operation Outdoor -33 C – +45 C
- 3.10 Operation Outdoor -33 C – +55 C
- 3.11 Operation Mast-Mounted Equipment -33 C – +45 C
- 3.12 Operation Mast-Mounted Equipment -40 C – +55 C
- 4 Climate Protection
- 5 EMC Capabilities
- RBS 2101, Product Description
- RBS 2102, Product Description
- RBS 2103, Product Description
- RBS 2202, Product Description
- RBS 2101, 2102, 2103 & 2202 Radio Configurations
- RBS 2202 Antenna Configurations
- ACCU Description
- BFU Description
- CDU-A Description
- CDU-C Description
- CDU-C+ Description
- CDU-D Description
- DXU Description
- DXU-21 Description
- ECU Description
- PSU -48 V Description
- PSU 230 V Description
- sTRU Single Transceiver Unit Description
- V3 Climate Unit Description
- Glossary
CDU-DCombining and Distribution Unit
2 Dimensions
This section describes the physical dimensions of CDU-D. It has the physical
size of three CDU-As, CDU-Cs or CDU-C+s. Dimensions and weight of CDU-D
are given in the table below.
Table 1 CDU-D Dimensions
Height Width Depth Weight
400 mm 483 mm 270 mm 45 kg
3 Power Consumption and Heat Generation
This section describes power consumption and heat generation for CDU-D.
Table 2 Power Consumption and Heat Generation
Max. Power Consumption Max. Heat Generation
120 W 300 W
4 Function Description
This section describes the functions of CDU-D. The CDU-D can be divided into
the following functional parts:
• TX part
• RX part
The figure below shows a block diagram of CDU-D (GSM 900/1800) with
duplexer.
4 (12)
EN/LZT 720 0279 Uen R1A