User Manual
Table Of Contents
- Contents
- 1 Introduction
- 2 Product Safety Requirements RBS 2000
- 3 Environmental Capabilities
- 3.1 Scope
- 3.2 Terminology
- 3.3 References
- 3.4 Transport -40 C – +70 C
- 3.5 Storage -25 C – +55 C
- 3.6 Handling -40 C – +70 C
- 3.7 Operation Indoor +5 C – +40 C
- 3.8 Operation Outdoor -33 C – +40 C
- 3.9 Operation Outdoor -33 C – +45 C
- 3.10 Operation Outdoor -33 C – +55 C
- 3.11 Operation Mast-Mounted Equipment -33 C – +45 C
- 3.12 Operation Mast-Mounted Equipment -40 C – +55 C
- 4 Climate Protection
- 5 EMC Capabilities
- RBS 2101, Product Description
- RBS 2102, Product Description
- RBS 2103, Product Description
- RBS 2202, Product Description
- RBS 2101, 2102, 2103 & 2202 Radio Configurations
- RBS 2202 Antenna Configurations
- ACCU Description
- BFU Description
- CDU-A Description
- CDU-C Description
- CDU-C+ Description
- CDU-D Description
- DXU Description
- DXU-21 Description
- ECU Description
- PSU -48 V Description
- PSU 230 V Description
- sTRU Single Transceiver Unit Description
- V3 Climate Unit Description
- Glossary
RBS 2101, RBS 2102, RBS 2103 and RBS 2202 Hardware Reference Manual
3.6.5 Mechanically Active Substances
During Handling the equipment withstands the conditions stated in Section
3.4.5 on page 11 in this document.
3.6.6 Mechanical Conditions
The equipment endures stresses normal for handling, during handling the
equipment withstand the conditions stated in Section 3.4.6 on page 11 in this
document.
3.7 Operation Indoor +5
C – +40
C
3.7.1 General Conditions
The severity of these requirements is in conformity with: IEC 721-3-3 classes
3K3/3Z2/3Z4/3B1/3C2(3C1)/3S2/3M1. and ETS 300 019-1-3 Class 3.1
"TEMPERATURE-controlled locations".
This clause refers to the environment which an RBS for indoor use shall endure.
Note: The different operating temperature levels according to Safe function
and Non-destruction, refer to situations where the RBS is supposed to
have been operating in "normal condition" mode for a certain time.
Then the surrounding temperature in the compartment increases
(decreases) according to these figures. Accordingly, this means that
the surrounding temperature is allowed to change within the limits while
the RBS still operates and has its own loss of energy.
3.7.2 Climatic Conditions
The severity of these requirements are in conformity with: IEC 721-3-3 classes
3K3/3Z2/3Z4. and ETS 300 019-1-3 Class 3.1.
Table 7 Climate limits for indoor operation
Value Temp. Relative
humidity
Absolute
humidity
Change of
temp.
Normal
condition
+5 - +40
C
5 - 85%
1 - 25 g/m
3
0.5
C/min
Excep-
tional/Safe func-
tion
+/-0 - +45
C
5 - 90%
1 - 25 g/m
3
0.5
C/min
Non Destruction
-10 - +55
C
5 - 90%
1 - 25 g/m
3
0.5
C/min
15EN/LZT 720 0023 Uen R3B 2010-06-10