User Manual
Table Of Contents
- Contents
- 1 Introduction
- 2 Product Safety Requirements RBS 2000
- 3 Environmental Capabilities
- 3.1 Scope
- 3.2 Terminology
- 3.3 References
- 3.4 Transport -40 C – +70 C
- 3.5 Storage -25 C – +55 C
- 3.6 Handling -40 C – +70 C
- 3.7 Operation Indoor +5 C – +40 C
- 3.8 Operation Outdoor -33 C – +40 C
- 3.9 Operation Outdoor -33 C – +45 C
- 3.10 Operation Outdoor -33 C – +55 C
- 3.11 Operation Mast-Mounted Equipment -33 C – +45 C
- 3.12 Operation Mast-Mounted Equipment -40 C – +55 C
- 4 Climate Protection
- 5 EMC Capabilities
- RBS 2101, Product Description
- RBS 2102, Product Description
- RBS 2103, Product Description
- RBS 2202, Product Description
- RBS 2101, 2102, 2103 & 2202 Radio Configurations
- RBS 2202 Antenna Configurations
- ACCU Description
- BFU Description
- CDU-A Description
- CDU-C Description
- CDU-C+ Description
- CDU-D Description
- DXU Description
- DXU-21 Description
- ECU Description
- PSU -48 V Description
- PSU 230 V Description
- sTRU Single Transceiver Unit Description
- V3 Climate Unit Description
- Glossary
RBS 2101, RBS 2102, RBS 2103 and RBS 2202 Hardware Reference Manual
Requirements
Table 4 Mechanical parameters during transport
Environmental Parameters Unit Value
Vibration sinus:
displacement
mm
3.5
acceleration m/s
2
10 15
frequency Hz
2 - 9 9 - 200 200 -
500
Random ASD: m
2
/s
3
1.0
frequency Hz
2 - 200
Shock:
peak acceleration m/s
2
100
duration
ms
11
3.5 Storage -25
C – +55
C
3.5.1 General Conditions
The severity of the requirements is in conformity with: IEC 721-3-1 classes
1K4/1Z2/1Z3/1Z5/1B2/1C2/1S3/1M2, and ETS 300 019-1-1 Class 1.2.
"WEATHERPROTECTED, not temperature-controlled storage".
During storage the equipment must be packaged. The values in these
conditions are valid for a maximum storage time of 12 months. The time refers
to equipment in its outer package and stored at the consignee in a conditioned
store.
3.5.2 Climatic Conditions
The equipment must be in packaged condition.
The severity of these requirements is in conformity with IEC 721-3-1 classes
1K4/1Z2/1Z3/1Z5. and ETS 300 019-1-1 class 1.2.
12