User Manual
Table Of Contents
- Contents
- 1 Introduction
- 2 Product Safety Requirements RBS 2000
- 3 Environmental Capabilities
- 3.1 Scope
- 3.2 Terminology
- 3.3 References
- 3.4 Transport -40 C – +70 C
- 3.5 Storage -25 C – +55 C
- 3.6 Handling -40 C – +70 C
- 3.7 Operation Indoor +5 C – +40 C
- 3.8 Operation Outdoor -33 C – +40 C
- 3.9 Operation Outdoor -33 C – +45 C
- 3.10 Operation Outdoor -33 C – +55 C
- 3.11 Operation Mast-Mounted Equipment -33 C – +45 C
- 3.12 Operation Mast-Mounted Equipment -40 C – +55 C
- 4 Climate Protection
- 5 EMC Capabilities
- RBS 2101, Product Description
- RBS 2102, Product Description
- RBS 2103, Product Description
- RBS 2202, Product Description
- RBS 2101, 2102, 2103 & 2202 Radio Configurations
- RBS 2202 Antenna Configurations
- ACCU Description
- BFU Description
- CDU-A Description
- CDU-C Description
- CDU-C+ Description
- CDU-D Description
- DXU Description
- DXU-21 Description
- ECU Description
- PSU -48 V Description
- PSU 230 V Description
- sTRU Single Transceiver Unit Description
- V3 Climate Unit Description
- Glossary
RBS 2101, RBS 2102, RBS 2103 RBS 2202 Radio Configurations
6.2.2 CDU-A Configurations
The CDU-A configurations for RBS 2102 and RBS 2202 are shown in the
table below.
Table 5 CDU-A Configurations
TMA
Cell or sector:
Number of
Antennas
Cell or sector:
Allowed
number
of TRUs
Cell or sector:
SCC Configura-
tion
No. of
cabinets
1 2 3 1 2 3 1 2 3
3x2 3xA9d_2.2 1 no no no 2 2 2 0–2 0–2 0–2
3xA18_2.2 1 M M M 2 2 2 0–2 0–2 0–2
3xA18_4.2 1 no no no 4 4 4 0–2 0–2 0–2
3xA19_2.2 1 M M M 2 2 2 0–2 0–2 0–2
3x4 3x[2xA18_2.2] 2 M M M 4 4 4 0–4 0–4 0–4
3x[2xA19_2.2] 2 M M M 4 4 4 0–4 0–4 0–4
3x[2xA9d_2.2] 2 no no no 4 4 4 0–4 0–4 0–4
M = Mandatory
Note: SCC 1x2, 1x4, 1x6 and 2x2 can be created with a subset of the 3x2
SCC. These configurations are not presented since they are not
regarded as separate configurations from a system point of view.
53 (74)
EN/LZT 720 0341 Uen R1A