User Manual
Table Of Contents
- Contents
- 1 Introduction
- 2 Product Safety Requirements RBS 2000
- 3 Environmental Capabilities
- 3.1 Scope
- 3.2 Terminology
- 3.3 References
- 3.4 Transport -40 C – +70 C
- 3.5 Storage -25 C – +55 C
- 3.6 Handling -40 C – +70 C
- 3.7 Operation Indoor +5 C – +40 C
- 3.8 Operation Outdoor -33 C – +40 C
- 3.9 Operation Outdoor -33 C – +45 C
- 3.10 Operation Outdoor -33 C – +55 C
- 3.11 Operation Mast-Mounted Equipment -33 C – +45 C
- 3.12 Operation Mast-Mounted Equipment -40 C – +55 C
- 4 Climate Protection
- 5 EMC Capabilities
- RBS 2101, Product Description
- RBS 2102, Product Description
- RBS 2103, Product Description
- RBS 2202, Product Description
- RBS 2101, 2102, 2103 & 2202 Radio Configurations
- RBS 2202 Antenna Configurations
- ACCU Description
- BFU Description
- CDU-A Description
- CDU-C Description
- CDU-C+ Description
- CDU-D Description
- DXU Description
- DXU-21 Description
- ECU Description
- PSU -48 V Description
- PSU 230 V Description
- sTRU Single Transceiver Unit Description
- V3 Climate Unit Description
- Glossary
RBS 2101, RBS 2102, RBS 2103 RBS 2202 Radio Configurations
5.3.4 Basic Configurations C+18d_2.2 and C+19d_2.2 with ALNA/TMA
The basic configurations C+18d_2.2 and C+19d_2.2 with ALNA/TMA are
shown in the figure below.
P002693A
ALNA/TMA
RXD
HCOMB
RXD
RXDA
CDU-C+
TRU
RXA
RXB
TX
TRU
RXA
RXB
TX
RXDA
DPX
RXB
Antennas
X
DPX
LNA
TX/RXA
X
DPX
LNA
Figure 21 Basic Configurations C+18_2.2 and C+19_2.2 with ALNA/TMA
Characteristics C+18_2.2 and C+19_2.2 with ALNA/TMA
Number of CDUs 1
Frequency band GSM 1800 or GSM 1900
Max. number of TRUs 2
Number of feeders 3
Number of antennas 2
Antenna configuration TX/RX + RX
Number of ALNAs/TMAs 2
33 (74)
EN/LZT 720 0341 Uen R1A