7.2 Operating Voltage
The RBS 2202 operating voltage is shown in the table below.
Table 11 Operating Voltage
Voltage Tolerance Frequency
200 240 V AC (single
phase)
180 264 V AC 50 60 Hz
-48 V DC/-60 V DC -40 to -72 V DC N/A
+24 V DC 20.5 29 V DC N/A
7.3 Power Consumption
The power consumption of the cabinet is shown in the table below.
Table 12 Power Consumption
Operation Power consumption (VA)
Normal (operation with peak load
and al
l time slots occupied)
2400
Maximum 3200
8 Transmission
The RBS 2202 is connected to a transmission interface G.703, type E1
(2 Mbits/s) or T1 (1.5 Mbits/s). For E1 interfaces, 75
coaxial or 120 twisted
pair cables are used. For T1 interfaces, 100
twisted pair cables are used.
9 External Alarms
The RBS 2202 can be connected to a maximum of 16 external alarms.
10 Product Approval
This section describes product approval for Europe and North America.
10.1 Europe
The RBS complies with the European Community directive R&TTE 1999/5/EC.
This means that the RBS fulfills legal requirements regarding product safety,
EMC (Electromagnetic Compatibility) and Radio.