User Manual
Table Of Contents
- Contents
- 1 Introduction
- 2 Product Safety Requirements RBS 2000
- 3 Environmental Capabilities
- 3.1 Scope
- 3.2 Terminology
- 3.3 References
- 3.4 Transport -40 C – +70 C
- 3.5 Storage -25 C – +55 C
- 3.6 Handling -40 C – +70 C
- 3.7 Operation Indoor +5 C – +40 C
- 3.8 Operation Outdoor -33 C – +40 C
- 3.9 Operation Outdoor -33 C – +45 C
- 3.10 Operation Outdoor -33 C – +55 C
- 3.11 Operation Mast-Mounted Equipment -33 C – +45 C
- 3.12 Operation Mast-Mounted Equipment -40 C – +55 C
- 4 Climate Protection
- 5 EMC Capabilities
- RBS 2101, Product Description
- RBS 2102, Product Description
- RBS 2103, Product Description
- RBS 2202, Product Description
- RBS 2101, 2102, 2103 & 2202 Radio Configurations
- RBS 2202 Antenna Configurations
- ACCU Description
- BFU Description
- CDU-A Description
- CDU-C Description
- CDU-C+ Description
- CDU-D Description
- DXU Description
- DXU-21 Description
- ECU Description
- PSU -48 V Description
- PSU 230 V Description
- sTRU Single Transceiver Unit Description
- V3 Climate Unit Description
- Glossary
RBS 2202Macro Indoor RBS
6.3 Operator Interface
The Man Machine Interface (MMI) in the RBS 2202 is comprised of optical
indicators, buttons and switches on units in the cabinet. The information here is
general. For a more detailed description of the indicators, buttons and switches
on the various RUs in the cabinet, see the respective units’ description in this
manual.
Optical Indicators
Several unit in the RBS have optical indicators that show the operational status
of the unit. The indicators reflect faults, mode change and operation.
Buttons and Switches
Buttons and switches can be found on several RUs. The table below takes into
account only the buttons on the DXU and TRUs.
Table 10 Buttons
Button Description
TRU reset Resets the TRU
DXU reset Resets the DXU
Local/remote mode Changes the mode between local and remote.
On the TRU this applies to the TRU only, on the
DXU this applies to the whole RBS.
Test call Not used
Barcode
The barcode for product identification is readable without disrupting RBS
function.
7 Power System
The RBS 2202 power system consists of the 200 – 240 V AC supply voltage
inputs, internal DC power supply, and an optional battery back-up system.
7.1 Power Supply
The RBS 2202 operates on 200 – 240 V AC, -48 to -60 V, or +24 V DC.
Note: A lockable mains disconnect switch must be provided close to the
RBS 2202 to facilitate maintenance and repair activities.