User Manual
Table Of Contents
- Contents
- 1 Introduction
- 2 Product Safety Requirements RBS 2000
- 3 Environmental Capabilities
- 3.1 Scope
- 3.2 Terminology
- 3.3 References
- 3.4 Transport -40 C – +70 C
- 3.5 Storage -25 C – +55 C
- 3.6 Handling -40 C – +70 C
- 3.7 Operation Indoor +5 C – +40 C
- 3.8 Operation Outdoor -33 C – +40 C
- 3.9 Operation Outdoor -33 C – +45 C
- 3.10 Operation Outdoor -33 C – +55 C
- 3.11 Operation Mast-Mounted Equipment -33 C – +45 C
- 3.12 Operation Mast-Mounted Equipment -40 C – +55 C
- 4 Climate Protection
- 5 EMC Capabilities
- RBS 2101, Product Description
- RBS 2102, Product Description
- RBS 2103, Product Description
- RBS 2202, Product Description
- RBS 2101, 2102, 2103 & 2202 Radio Configurations
- RBS 2202 Antenna Configurations
- ACCU Description
- BFU Description
- CDU-A Description
- CDU-C Description
- CDU-C+ Description
- CDU-D Description
- DXU Description
- DXU-21 Description
- ECU Description
- PSU -48 V Description
- PSU 230 V Description
- sTRU Single Transceiver Unit Description
- V3 Climate Unit Description
- Glossary
RBS 2202 Macro Indoor RBS
The compliance boundary is defined as a cylinder around the antenna, see
figure below. The antenna is not located at the centre of the cylinder. Instead
it is located almost at the edge, facing in towards the center of the cylinder.
The distance between the antenna’s rear and the edge of the cylinder is the
"Distance behind antenna". The height of the cylinder is the antenna height
plus a certain distance above and below the antenna. The cylinder shape
overestimates the compliance distances right beside the antenna.
P009694A
Diameter
Height
Antenna
Distance
behind
antenna
Figure 4 Complian
ce Boundary Cylinder
Note: Table 5 on page 10 shows an example for a typical antenna. As the
antenna field distributions will differ for different, complete calculations
or measurements m
ay be necessary in order to establish the
compliance boundary for other configurations chosen by the customer.
For further information on calculation methods, see:
Radio Site Installation Engineering
Manual
EN/LZN 720 0069
9 (20)
EN/LZT 720 0223 Uen R2A