Table 9 Sound Pressure Levels for an RBS against a Wall, with Combined Climate Unit
Calculated Distance in Metres, Each Direction
Without Sound Hood With Sound Hood
Temp.
Sound
Pressure
Level,
dBA
Front Left Right Front Left Right
35 44 30 32 18 17 18
40 25 16 18 10 9 10
50
755
323
45
60 2<1<1<1<1<1
5.2.3 Acoustic Dispersion with Heat Exchanger (RBS 2106)
The cabinet noise dispersion for an RBS 2106 with Heat Exchanger Climate Unit
is shown in the tables below. The figures and tables show the noise dispersion
generated by a free-standing cabinet and by a cabinet mounted against a wall.
Note: The acoustic noise dispersion values for a free-standing cabinet and a
cabinet installed against a wall were tested according to the ISO 9614-2
standard. Deviations from these values can be experienced due to the
nature of materials in the environment where the cabinet is installed.
Objects near the cabinet can reflect or absorb sound and thus affect
acoustic dispersion.
The following two tables show the sound pressure levels, calculated at the
bystander position at a distance of 1 metre from the cabinet and 1.5 metre
above the floor. The calculations are valid in free field. If the RBS is placed in a
room the sound pressure level will be higher than indicated in the tables below.
Table 10 Sound Pressure Level, Bystander Position without Sound Hood
Sound Pressure Level at the Bystander Position at a
Distance of one metre, L
pA
dB
Operating
Condition
Front Left Right Back
15
C
49 47 47 45
20
C
55
52 52 48
25
C
59 56 56 52
30
C
62 59 59 53
Table 11 Sound Pressure Level, Bystander Position with Sound Hood
Sound Pressure Level at the Bystander Position at a
Distance of one Metre, L
pA
dB
Operating
Condition
Front Left Right Back
15
C
45 45 44 45