Reference Manual
Table Of Contents
- RBS 2206 Reference Manual
- Contents
- Preface
- Product Safety Requirements RBS 2000
- Environmental Capabilities
- Scope
- Terminology
- References
- Transport -40 C - +70 C
- Storage -25 C - +55 C
- Handling -40 C - +70 C
- Operation Indoor +5 C - +40 C
- Operation Outdoor -33 C - +40 C
- Operation Outdoor -33 C - +45 C
- Operation Outdoor -33 C - +55 C
- Operation Mast Mounted Equipment -33 C - +45 C
- Operation Mast Mounted Equipment -33 C - +55 C
- Radio Configurations, RBS 2206
- Product Data
- Unit Description, DXU-21
- Unit Description, dTRU
- Unit Decription, CDU-G and CDU-F
- Unit Description, CXU-10
- Unit Description, FCU-01
- Unit Description, DC-Filter 01
- Unit Description, PSU 1200 W
- Unit Description, ACCU/DCCU
- Unit Description, IDM
- Broadcast
- Common Control Channel Handling
- Physical Channel Handling
- Speech and Data Services
- Packet Data Services
- Call Control
- References
- Channel Activation
- Adaptive Frame Alignment
- Asynchronous Handover Detection
- RF Channel Release
- Deactivate SACCH
- Link Establish Indication
- Link Release Indication
- Link Establishment Request
- Link Release Request
- Transparent Message Transmission
- Transparent Message Reception
- SACCH Info Modify
- LAPDm
- Channel Reactivation
- Power Information
- GPRS, Physical Link Layer
- Base Station Power Control
- Channel Measurements
- Discontinuous Transmission
- Frequency Hopping
- Encryption
- Mode Modify
- Mobile Station Power Control
- Short Message Service
- Diversity Supervision
- Synchronization
- Radio Reception
- Radio Transmission
- Frequency Allocation Support
- Restart and Recovery
- Function Change
- Functionality Administration
- Operation and Maintenance Support
- References
- Concepts
- Buttons
- Change RU to Local Mode
- Change RU to Remote Mode
- Change RU to Remote Mode Cancel
- Change SW Power Boost Slave RU to Local Mode
- Loop Control
- RF Loop Test Supervision
- Calendar Time Request
- RSSI Temperature Compensation
- Max Cooling
- Fault Indicator
- BS Fault Indicator
- Operational Indicator
- Tx Not Enabled Indicator
- Local Mode Indicator
- External Alarms Indicator
- DC Disconnected Indicator
- Battery Mode Indicator
- Bat Disconnected Indicator
- AC Fault Indicator
- Test Result Indicators (not used)
- Local Mode in Progress
- Installation Data Handling
- Self Test and Supervision
- Diagnostics and Fault Handling
- Operation and Maintenance Terminal
- External Alarms
- Handling of Auxiliary Equipment
- Climate Protection
- EMC Capabilities
- Transmission Interface Handling G.703 2048 kbit/s
- Transmission Interface Handling DS1 1544 kbit/s
- Terrestrial Link Handling
- Channel Distribution Function
- Transport network O&M functions-DXX Support
- BTS Parameter Limitations
- Glossary
Product Description 36 (33)
© Ericsson. Commercial in confidence Rev B 2001-05-16 SRN/X-00:146
8 Dual Band GSM 900/1800 Radio Specification
The operating specifications of the radio equipment will in most cases exceed the
performance requirements specified in the GSM Technical Specifications.
The Dual Band BTS comprises equipment for both GSM 900 and GSM 1800.
8.1 System Data
The System Data, for the Dual Band RBS are the same as for the GSM 900 and the GSM
1800.
8.2 Configurations Dual Band RBS
Table 15. Configurations for Dual band with CDU-G.
Max
Config
(900|1800)
No. of
cabinets
TMA Number of
CDU’s
Number of Antennas
1
CDU
type
1x4|1x4 1 Opt. 2 (2)|(2) G
1x8|1x4 1 Opt. 3 (4)|(2) G
1x4|1x8 1 Opt. 3 (2)|(4) G
Table 16. Configurations for Dual Band with CDU-F and the hybrids used in the dTRU’s
(combined mode).
Max
Config
(900|1800)
No. of
cabinets
TMA Number of
CDUs
Number of Antennas
1
CDU
type
1x4|1x4 1 Opt. 2 (2)|(2) F
1x8|1x4 1 Opt. 3 (2)|(2) F
1x4|1x8 1 Opt. 3 (2)|(2) F
1
The number of physical antennas is reduced if cross-polarised antennas are used.