Specifications

5
- it transmits events occurred at the objective protected by the burglary control
panel only as SMS messages to the mobile phone of the objective’s owner;
- it transmits events occurred at the objective protected by the burglary control
panel both to a monitoring station and as SMS messages as well, to the mobile
phone of the objective’s owner.
Define the phone number of the monitoring station and/or of the mobile phone of
the alarm system’s owner within the configuration SMS in order to select the
functioning mode.
Events generated by the burglary control panel are taken and forwarded to the
monitoring station and/or the mobile phone of the client. The message containing
these events also contains the control panel’s account number.
If the regular phone line is present, the events are directly sent on the phone line
(being ignored by the communicator). If the regular phone line is not present, the
events are taken by the communicator and redirected through GSM.
The events generated by the communicator are: phone line loss/restoring,
communicator’s local inputs activation/deactivation, weak GSM signal and
periodical test. A 4 HEX digit account number should be defined for these events.
These events (generated by the GSM communicator) are transmitted through GSM,
irrespective of the phone line status.
TECHNICAL FEATURES
DTMF communication formats of the alarm control panel
- ADEMCO Express 4x2;
- Contact ID (PID)
Available inputs and outputs
- 6 inputs with programmable codes for activation and deactivation;
- 6 “open collector” outputs, used for automations (upon construction).
Functioning indicators
The module has got a green signaling LED, indicating GSM phone presence and
proper functioning;
Consumption
- supply voltage:
mains - 220V
ac
;
12V / 4A
rechargeable battery;
- maximum current consumption @ 12V
dc
(including GSM phone loading):
500mA;
- average current consumption @ 12V
dc
(loaded GSM phone): 40mA.