4.
Route the fiber optical cables to the
connectors inside the RRU-N as
shown in the picture. Remove the
protective caps on the fibers and the
connectors. Insert the cable into the
specified connectors of the RRU-N.
Note: Do not touch the end of
the optical connectors after the
protective caps are removed.
K000354C
TX RX
L
o
c
a
l R
e
s
e
t
T
e
s
t
R
T
5.
Adjust the cable so that a small part
of the cable jacket is visible inside
the RRU-N.
Fasten the cable gland nut and
tighten it properly using a 17 mm
open end wrench. Ensure that the
cable gland is sealed.
Note: The cable must be attached
to the pole, mast or wall with cable
ties or straps.
K000355C
PWR
OPT
5 Nm
6.
Fit the RRU-N cover into position
and tighten the captive screws to
a torque of 1 Nm, using a torque
driver fitted with a Torx bit T20.
K000348B
!