User's Manual

Ericsson Internal
INSTALLATION INSTR. 22 ( 37 )
/ XKUEMHU 50/1531-LZA 701 0001 Uen
CBC/ XRX ( Jan-Erik Thillberg) 2009-03-09 C
Prepared (also subject responsible if other) No.
Approved Checked Date Rev Reference
3.2.6 Connecting Optical Fiber Cable and Setting RRU-N Configuration
Caution!
Stop! This product contains components sensitive to ESD. Use an approved
ESD wrist strap, connected to the product grounding point, to avoid damaging
these components.
Note: The cables are fiber optic and must be handled with care. The minimum
allowed bending radius for the fiber optical cables is 50 mm. The
minimum allowed bending radius for each individual fiber is 20 mm.
Note: Avoid damaging the cable by attaching the pulling wire properly. The
pulling force must not exceed 300 N.
To connect the optical fiber cable to the RBS 2111 RRU-N, perform the
following steps: