User's Manual

Ericsson Internal
INSTALLATION INSTR. 21 ( 37 )
/ XKUEMHU 50/1531-LZA 701 0001 Uen
CBC/ XRX ( Jan-Erik Thillberg) 2009-03-09 C
Prepared (also subject responsible if other) No.
Approved Checked Date Rev Reference
7.
Connect the conductors as shown
in the picture. Tighten the wire
connected to the terminal block to a
torque of 0.8 Nm.
Note: Ensure that the wires are
connected to the correct polarities.
K000469B
T
X
R
X
Loc
a
l Reset
T
est
12
-4
8
V
0
V
8.
Fasten the cable gland nut and
tighten it properly using a 20 mm or
24 mm open-ended wrench. Ensure
that the cable gland is sealed.
K000351C
PWR
5 Nm
9.
Fit the RRU-N cover into position
and tighten the captive screws to a
torque of 1 Nm, using a torque driver
fitted with a Torx bit T20.
K000348B
!
If the RRU-N is equipped with an PSU-AC to adopt the AC power, perform the
steps in Section 5 on page 30.