User's Manual

Ericsson Internal
INSTALLATION INSTR. 20 ( 37 )
/ XKUEMHU 50/1531-LZA 701 0001 Uen
CBC/ XRX ( Jan-Erik Thillberg) 2009-03-09 C
Prepared (also subject responsible if other) No.
Approved Checked Date Rev Reference
5.
Remove the cable gland nut from
the cable gland using a 24 mm
open-ended wrench. Remove the
protective plug and the inner seal
from the cable gland (marked PWR).
K000349C
PWR
6.
Route the cable through the nut,
the inner seal and the gland of
the RRU-N. Wrap the cable shield
around the lower part of the inner
seal, as shown in the figure. Turn
the inner seal so that the guide lines
up with the grove, and then insert
it into the gland. Do not tighten the
gland yet.
Note: Ensure that the cable has
already been attached to the pole,
mast or wall with cable ties or straps.
Note: Be very careful to ensure
that the nut does not slide down the
cable making it impossible to reach.
K000475B
PWR