To connect the -48 V DC power to the RRU-N, perform the following steps:
1.
Ensure that the external DC power is switched off before connecting the cable.
2.
Loosen the six captive screws on
the cover of the RRU-N, and release
the cover.
Note: The cover is attached to the
RRU-N by means of a short cord,
so the cover can be released and
allowed to hang free.
K000348B
!
3.
Cut the power supply cables to the appropriate length.
4.
Strip approximately 60 mm of the
outer layer of insulation from the
power cable. Leave approximately
10 mm of the inner conductors.