DESCRIPTION 9 ( 46 )
/ XSNSIXI 198/1551-LZA 701 0001 Uen
CBC/XRX/M (Kai Lian) 2011-05-05 C
Prepared (also subject responsible if other) No.
Approved Checked Date Rev Reference
On a pole
In a 19 inch rack
The distance between MU and RRU-N is limited by the maximum length of the
optical fiber connecting the two units, which is 500 m. The RBS 2111 Second
Generation supports a length up to 3 km.
Note: When mounting the MU on a pole, it is recommended that the front
sunshield is positioned such that the MU is protected from the sun as
much as possible.
4.1 Space Requirements for Wall-Mounting of MU
This section describes the installation requirements, drill pattern and site layout.
4.1.1 Installation Requirements for Wall-Mounting
The MU must always be vertically mounted.
The wall must have a fairly level surface. The wall gradient must not exceed
5 mm/m.
The drill patterns are shown in the figures below. A drilling template for
wall-mounting is delivered with the wall-mounting kit for the MU.
K000241C
Unit of measurement: mm
20
20
36.5
36.
5
Ø11
10x
20
150
UP
UP
MU-12
wall mounting drill template
Figure 3 Drill Pattern