Figure 26 Connection Interfaces
9.2 –48 V DC Power Interface
The interface accepts a cable area of 2 x 6 mm². The cable gland for the
RRU-N accepts a cable diameter of 6 12 mm.
It is recommended to use a cable area of 2 x 6 mm² for power cable lengths
up to 60 m. The maximum voltage drop of the cable should be less than 3 V
DC. A shielded power cable connected to the RRU-N must be used, which is
connected to the ground on both the RRU-N and the power supply equipment
side. Otherwise the overvoltage and lightning protection function of the RRU-N
will fail.
The figure below shows the power interface.