User's Manual
Table Of Contents
- toc
- RBS Product Description
- 1 Introduction
- 2 Product Overview
- 3 Dimensions
- 4 Space Requirements for MU
- 5 Space Requirements for RRU-N
- 6 Environment
- 7 Hardware Units RBS 2111 Second Generation
- 8 MU Connection Interfaces
- 9 RRU-N Connection Interfaces
- 10 Power System
- 11 Transmission
- 12 External Alarms
- 13 Standards, Regulations and Dependability
- RBS Product Description
- tables
- Table 1 The MU Dimensions
- Table 2 The MU Weight
- Table 3 The MU Colour
- Table 4 The RRU-N Dimensions
- Table 5 The RRU-N Weight
- Table 6 The RRU-N Colour
- Table 7 Times for Cold Startup and Restart
- Table 8 Normal Conditions During Outdoor Operation
- Table 9 Mechanical Conditions During Outdoor Operation
- Table 10 Heat Dissipation
- Table 11 Compliance Boundary Dimensions for General Public (GP)
- Table 12 Characteristics for the Typical Antenna
- Table 13 Total Power to the Antenna for Typical RBS Configuratio
- Table 14 Hardware Units
- Table 15 Standard Hardware Units
- Table 16 MU Connection Interfaces
- Table 17 RRU-N Connection Interfaces
- Table 18 Antenna Connection
- Table 19 DC Supply Voltage Requirements for MU and RRU-N
- Table 20 Fuse Recommendation for MU and RRU-N
- Table 21 Power Consumption
Ericsson Internal
DESCRIPTION 37 ( 46 )
/ XSNSIXI 198/1551-LZA 701 0001 Uen
CBC/XRX/M (Kai Lian) 2011-05-05 C
Prepared (also subject responsible if other) No.
Approved Checked Date Rev Reference
K000346B
F
a
u
l
t
O
p
e
r
a
t
io
n
a
l
L
o
c
a
l
m
o
d
e
R
F
o
ff
O
PT
P
W
R
D
C
B
A
A
N
T
1
A
N
T
2
Figure 25 Connection Interfaces
Table 17 RRU-N Connection Interfaces
A Grounding interface
B Optical fiber interface
C Power interface
D Antenna interface
9.1 Grounding Interface
The RRU-N must be grounded to prevent damage that may result from
overvoltage and lightning.
Earth grounding point for the RRU-N is an M8 threaded stud. The figure below
shows the grounding interface.