User's Manual

Table Of Contents
Ericsson Internal
DESCRIPTION 27 ( 46 )
/ XSNSIXI 198/1551-LZA 701 0001 Uen
CBC/XRX/M (Kai Lian) 2011-05-05 C
Prepared (also subject responsible if other) No.
Approved Checked Date Rev Reference
Table 15 Standard Hardware Units
A Remote Radio Unit-N (RRU-N)
B Sun shield
C Cover plate
D Connection interfaces
7.2.1 RRU-N
The Radio Remote Unit-N (RRU-N) has the following main functions:
Transmits and receives two radio carriers
Two receivers per TRX for RX diversity
The RRU-Ns are installed with the internal SPD.
The RRU supports GMSK, 8-PSK, 16-QAM and 32-QAM, as well as Voice
services over Adaptive Multi-user channels on One Slot (VAMOS).
7.2.2 Cover Plate
The cover plate protects the connections for optical fibers and power cables.
7.2.3 Connection Interfaces
The connection interfaces for the RRU-N are described in Page 36.
7.3 Optical Fiber
An optical fiber makes the connection between the MU and the RRU-N. There
are four different lengths available for the optical cables: 20 m, 50 m, 100 m
and 500 m. The optical fiber must have zero-dispersion in the wavelength
range 1310 nm.
The maximum supporting length of the optical fiber cable is 3 km, which can be
built by the user according to the cable specifications:
The cable contains two strain-relieved fibers. The fibers are well protected
at the fan-out end.
It is recommended to use swell-able tape, or another similar solution. It is
not recommended to use the filling jelly.
The strength member can be fiber reinforced plastic (FRP) rod or Aramide
yarn to fulfill the mechanical requirements.
The maximum outer diameter is 10 mm.
Mechanical Requirements