DESCRIPTION 19 ( 46 )
/ XSNSIXI 198/1551-LZA 701 0001 Uen
CBC/XRX/M (Kai Lian) 2011-05-05 C
Prepared (also subject responsible if other) No.
Approved Checked Date Rev Reference
Description Temperature Relative Humidity
Storage
-25
C to +55
C
10 100%
Handling
-40
C to +70
C
5 100%
6.2 Mast Vibrations
This section describes the mast vibration tolerance supported by the MU and
RRU-N.
The equipment complies with the following:
IEC 721-3-4 class /4M5/
ETSI EN 300 019-1-4 class 4.1
Table 9 Mechanical Conditions During Outdoor Operation
Environmental Parameter Unit Value
Vibration
sinusoid:
(1)
frequency Hz
2 9 9 200
displacement
mm
0.6
acceleration m/s²
2
Vibration
random:
ASD
(2)
m²/s³
0.05 0.1 0.2
frequency Hz
5 200
duration of exposure min 30/direction
no. of test directions
3
Shock: peak acceleration m/s²
100
(3) (4)
duration
ms
11
(1) These requirement shall be used for verification of structural sustainability only, for
functional verification random vibration shall be used.
(2) ASD = Acceleration Spectral Density.
(3) The requirement belong to ’Exceptional/Safe function’ with the exemption:
performance of the RBS shall be verified as ’no loss of calls’ or ’loss of establish
radio link.
(4) The shock requirement shall be used for RBS’s mechanical and structural strength
test, and functional verification of RBSs that are allowed to be mounted on non
ground-based foundations. The random vibration requirement already cover all
possible excitations that ground-based foundation installation can be subjected to.