User's Manual
Table Of Contents
- toc
- RBS Product Description
- 1 Introduction
- 2 Product Overview
- 3 Dimensions
- 4 Space Requirements for MU
- 5 Space Requirements for RRU-N
- 6 Environment
- 7 Hardware Units RBS 2111 Second Generation
- 8 MU Connection Interfaces
- 9 RRU-N Connection Interfaces
- 10 Power System
- 11 Transmission
- 12 External Alarms
- 13 Standards, Regulations and Dependability
- RBS Product Description
- tables
- Table 1 The MU Dimensions
- Table 2 The MU Weight
- Table 3 The MU Colour
- Table 4 The RRU-N Dimensions
- Table 5 The RRU-N Weight
- Table 6 The RRU-N Colour
- Table 7 Times for Cold Startup and Restart
- Table 8 Normal Conditions During Outdoor Operation
- Table 9 Mechanical Conditions During Outdoor Operation
- Table 10 Heat Dissipation
- Table 11 Compliance Boundary Dimensions for General Public (GP)
- Table 12 Characteristics for the Typical Antenna
- Table 13 Total Power to the Antenna for Typical RBS Configuratio
- Table 14 Hardware Units
- Table 15 Standard Hardware Units
- Table 16 MU Connection Interfaces
- Table 17 RRU-N Connection Interfaces
- Table 18 Antenna Connection
- Table 19 DC Supply Voltage Requirements for MU and RRU-N
- Table 20 Fuse Recommendation for MU and RRU-N
- Table 21 Power Consumption
Ericsson Internal
DESCRIPTION 16 ( 46 )
/ XSNSIXI 198/1551-LZA 701 0001 Uen
CBC/XRX/M (Kai Lian) 2011-05-05 C
Prepared (also subject responsible if other) No.
Approved Checked Date Rev Reference
K000372A
250
300
300
250
250
Figure 10 Site Layout
5.2 Space Requirements for Pole-Mounting of RRU-N
This section describes the installation requirements and site layout.
5.2.1 Installation Requirements for Pole-Mounting
The RRU-N must always be vertically mounted and close to the antenna.
The pole diameter must be within 60 – 120 mm.