Figure 5 Installation Requirements for Pole-Mounted MU
4.2.2 Site Layout
The 200 mm of free space above and 250 mm below the MU are recommended
to ensure sufficient airflow. It is recommended that the space between two
MUs side by side is 250 mm.
The minimum space of 1000 mm is recommended in front of the MU to provide
adequate workspace.
4.3 Space Requirements for Rack-Mounting of MU
This section describes the installation requirements and site layout.
4.3.1 Installation Requirements for Rack-Mounting
The minimum free rack space height is 89 mm (2 U), which includes space
for cables.
The totally minimum required installation depth is 410 mm. The minimum 19
inch rack depth is 290 mm, and the 120 mm of free space in front of the 19
inch rack is required.
The mounting brackets on the both side of MU can be adjusted, but there must
be a minimum 50 mm free space in front of the cable glands.
The installation requirements are shown in the figures below.