4.1.2 Site Layout
The 200 mm of free space above and 250 mm below the MU are recommended
to ensure sufficient airflow. It is recommended that the space between two MUs
side by side is 250 mm, and the space between an MU and a corner is 500 mm.
The space of 1000 mm is recommended in front of the MU to provide adequate
workspace.
A
250
250
250
500
500
200
200
Figure 4 Site Layout
4.2 Space Requirements for Pole-Mounting of MU
This section describes the installation requirements and site layout.
4.2.1 Installation Requirements for Pole-Mounting
The MU must always be vertically mounted.
The pole diameter must be 60 120 mm.