Optional Installation External Splitter/Highway Function
4 Optional Installation External
Splitter/Highway Function
Caution!
Stop! This product contains components sensitive to ESD. Use an approved
ESD wrist strap, connected to the product grounding point, to avoid damaging
these components.
Note: The antenna system must have been tested. For more information, see
Verifying Antenna Systems, 1/1532-LZA 701 0001.
This section describes how to install the external splitter on a pole/mast and
how to connect the cables.
1.
Loosen the screw of the
mounting clamp, using a flat 6
mm screwdriver.
2.
Route each of the mounting
clamp through the mounting
plate of the splitter. Place them
in the correct position on the pole
and tighten the screw.
K000419A
2350/1531-LZA 701 0001 Uen PA4 2008-07-31