Installation RRU-N
4.
Route the fiber optical cables
to the connectors inside the
RRU-N as shown in the picture.
Remove the protective caps on
the fibers and the connectors.
Insert the cable into the specified
connectors of the RRU-N.
Note: Don't touch the end of
the optical connectors after the
protective caps are removed.
Note: The cables are fiber optic
and must be handled with care.
The minimum allowed bending
radius for the fiber optical cables
is 50 mm.
K000354C
TX RX
L
o
c
a
l R
e
s
e
t
T
e
s
t
R
T
5.
Adjust the cable so that a small
part of the cable jacket is visible
inside the RRU-N.
Fasten the cable gland nut and
tighten it properly using an 17
mm open end wrench. Ensure
that the cable gland is sealed.
Note: Avoid damaging the cable
by attaching the pulling wire
properly. The pulling force must
not exceed 300 N.
K000355C
PWR
OPT
5 Nm
6.
Fit the RRU-N panel into position
and tighten the captive screws
to a torque of 1.7 Nm, using a
torque driver fitted with a Torx
bit T20.
K000348B
!
1950/1531-LZA 701 0001 Uen PA4 2008-07-31