User's Manual
Table Of Contents
- toc
- 1 Introduction
- 2 Tools and Documentation
- 3 Installation RRU-N
- Introduction
- Target Group
- 3.1 Preconditions
- 3.2 Installation Procedure
- Figure 1 Workflow for Installing the RRU-N
- 3.2.1 Unpacking and Checking the Material
- 3.2.2 Installing RRU-N on a Pole or a Mast
- 3.2.3 Installing RRU-N on a Wall
- 3.2.4 Grounding RRU-N
- 3.2.5 Connecting the 48 V DC Power
- 3.2.6 Connecting Optical Fiber Cable and Setting RRU-N Configura
- 3.2.7 Connecting Antenna Cables
- 3.2.8 Installing the Front Sunshield
- 4 Optional Installation External Splitter/Highway Function
- 5 Optional Installation External Hybrid Combining Unit (EHCU)
- 6 Performing Concluding Routines
- 7 Verifying the Installation
- tables
RBS Installation Instructions
6.
Route the cable through the nut,
the inner seal and the gland
of the RRU-N. Wrap the cable
shield around the lower part of
the inner seal as shown in the
picture. Turn the inner seal so
that the guide lines up with the
grove, and then insert it into the
gland. Do not tighten the gland
yet.
Note: Ensure that the cable has
already been attached to the
pole, mast or wall with cable ties
or straps.
Note: Be very careful to ensure
that the nut does not slide down
the cable making it impossible
to reach.
K000475B
PWR
7.
Connect the conductors as
shown in the picture. Tighten the
wire connected to the terminal
block to a torque of 0.8 Nm.
Note: Ensure that the wires
are connected to the correct
polarities respectively.
K000469B
T
X
R
X
Loc
a
l Reset
Te st
12
-4
8
V
0
V
16 50/1531-LZA 701 0001 Uen PA4 2008-07-31