manual
888-60-539-W-01 rev.M • 03/12
13 of 22
1x
12
3
Programming New Codes (Default Master Code: 54321)
1
2
3
4
5
6
7
8
Restore Factory Default:
1 Enter Master Code
2 Press 1 and 3 simultaneously (while blinking)
3 Press 4 and 5 on number pad at the same time
Lock (2 methods):
• Wait 4 seconds to lock automatically
• Press 4 and 5 on number pad simultaneously
Unlock (3 methods):
• Enter Master Code.
• Enter Personal Code.
• Key - turn counter clockwise 1/8 turn
Lost Master Code
Contact Ergotron Customer Care for instructions.
Troubleshooting
• Key pad numbers are dark
-Touch anywhere on number pad to activate back-light, (remains locked
until you enter valid code)
-Check to make sure battery pack is connected
• Code is accepted but does not open
-make sure door is fully closed and lock engaged before entering code
• Door won’t open when Personal Code is entered
-Test system by entering Master Code. If door doesn’t unlock, follow
"Lost Master Code" instructions.
Flashing LED: Meaning
5: Door is open
1 & 3: Unit is ready to program master or user codes (see Programming New Codes)
1: Door is unlocked
All: New code accepted
Ensure that the batteries are installed in the battery pack.
Note: Ergotron has supplied the enclosed rechargeable batteries with su cient charge to operate the
electronics. However, if your product has been warehoused for an extended time before installation,
the batteries may need to be recharged prior to use. This can be done by connecting battery pack's USB
cable to a “powered up” CPU as de ned in step 4, or with an external NiMH battery charger (not supplied).
NOTE: User should change Master Code upon receipt of Enclosure.
13
Guía del usuario - Español
Manuel de l’utilisateur - Français
Gebruikersgids - Nederlands
Benutzerhandbuch - Deutsch
Guida per l’utente - Italiano
Svenska
ユーザーガイド : 日本語
用户指南 : 汉语
English
Enter Master Code on Keypad.
Numbers 1 and 3 on the Keypad will start ashing, indicating the Master Code has been accepted.
Simultaneously press 1 and 3 while they are ashing.
All the numbers will light (you have 3 seconds to enter a code).
Enter a new code—any sequence of 5 numbers. (The rst code programmed is the new Master Code.)
When the code is accepted, all of the LEDs will ash once in acknowledgement (you have 3 seconds to enter the next code).
You can then proceed to program up to 10 personal codes by repeating steps 5 and 6.
When nished entering new codes, system will exit program mode after 3 seconds with a series of LED ashes.