Use and Care Manual
Initialization Setting:
Long press "up + down key" 4 seconds. At this moment, the LED display
flashing and shows "000", and the table lift down slowly at same time. When
table lifting down to lowest position, turn back a certain height , then stop .
Meanwhile, you can hear "beep" sound 2 times, initialization is successful.
If you loosen the button during initialization process, then initialization process
stop. The LED display shows “---“ if initialization failed . If you have done
initialization before, then the original data has been deleted.
Initialization function(Reset) description:
1. Before initializing , LED display shows as follows:
Fault code instructions:
E-1 Motor parameter error. Stop the power thoroughly and turn on again
with electricity. If still appear, back to the factory maintenance
E-2 Hall plate static current error. Check the motor line has failed to
disconnect.
E-3 The main low voltage power supply
E-4 Motor line open circuit. Check to see if the motor line connected
E-5 Over-current protection. Electrical short circuit or stuck the table.
E-6 Keep
E-7 Motor hall fault.
Anti-pinch function:
In the process of lifting, the table get stuck or blocked, the controller will stop
and go back immediately. At the same time LED display shows as follows:
2.
3.