Code Specs
TECHNICAL BULLETIN
Lift bucket third party load testing report .
© 2010 Tenacious Holdings, Inc. All Rights Reserved. All Wrongs Reversed. QUESTIONS? CALL 1-800-225-8238 9/29/2010
Test Method:
Each bucket/bag was filled to the listed load with lead weights. The bucket/bag was then lifted and
the load was allowed to hang for 15 minutes. The bag was then unloaded and examined for
damage.
Third Party Test Data:
Model
Dimensions
Swivel
Load
(lbs)
Observations
Max. Safe
Working Capacity
5730
12.5”D x 17”H
No
600
15 min. hold, stretch ¼” of bottom
seam, but no failure
150 lbs (68 kg)
5740
12.5”D x 17”H
Yes
600
15 min. hold, no damage
150 lbs (68 kg)
5732
10”D x 28”H
No
500
15 min. hold, no damage
125 lbs ( 57 kg)
5742
10”D x 28”H
Yes
500
15 min. hold, no damage
125 lbs ( 57 kg)
5733
12.5”D x 15”H
No
400
15 min. hold, no damage
100 lbs (45 kg)
5743
12.5”D x 15”H
Yes
400
15 min. hold, no damage
100 lbs (45 kg)
5734
10”D x 14”H
No
300
15 min. hold, no damage
75 lbs (34 kg)
5744
10”D x 14”H
Yes
300
15 min. hold, no damage
75 lbs (34 kg)
5735
16”D x 20”H
No
600
15 min. hold, stretch 1/8” of bottom
seam, but no failure
150 lbs (68 kg)
5745
16”D x 20”H
Yes
600
15 min. hold, no damage
150 lbs (68 kg)
5736
10”D x 13”H Tapered
No
300
15 min. hold, no damage
75 lbs (34 kg)
5746
10”D x 13”H Tapered
Yes
300
15 min. hold, no damage
75 lbs (34 kg)
5815
9”W x 15”L x 14”H
n/a
400
15 min. hold, no damage
100 lbs (45 kg)
5817
11”W x 18”L x 16”H
n/a
300
15 min. hold, no damage
75 lbs (34 kg)
Summary:
Based on the results of the testing, Ergodyne has certified each of the above products to a maximum
safe working capacity using a safety factor of 4. Please reference the above chart for exact
information.
Callibrated Test Equipment:
Interface Load Cell, 3000 lb capacity, ID PT-162-058, calibrated 7/23/2010, due 7/23/2011
HBM Load Cell, 10,000 lb capacity, ID MM110-029, calibrated 7/28/2010, due 5/28/2011
Third party documentation available upon request.