User guide
EG_GenPro2xe_1003_UG_005_UK Page 57 / 63
Descriptions and non-contractual illustrations in this document are given as an indication only.
ERCO&GENER reserves the right to make any modifications.
Dct_427_00
8.2.5 RESET signal
Cabling Scheme
Table: Conditions of use
Parameters Condition Min. Typ. Max. Unit
VIL Input Voltage – Low or float -0.3 0.8 Vdc
VIH Input Voltage – High 2 3.3 Vdc
RIPU Internal Pull-Up Resistor 5.38K Ohms
8.2.6 RF GSM/DCS characteristics
8.2.6.1 RF functioning
The RF functioning complies with the ETSI GSM Standards.
The RF performances for the receiver and the transmitter are described below.
Table: Parameters of the RF receiver and transmitter
Receiver
Sensitivity in 850/900 - 106 dBm, GPRS Coding Scheme 1 (CS1)
Sensitivity in 1800/1900 - 106 dBm, GPRS Coding Scheme 1 (CS1)
Transmitter
Maximum power (Power Class1 - 850/900)
at ambient temperature
33 dBm +/- 2 dB @ antenna connection
Maximum power (Power Class4 - 1800/1900)
at ambient temperature
30 dBm +/- 2 dB @ antenna connection