7.6 BOOT
This signal must NOT be connected, NOT used. Its use is strictly reserved for the manufacturer.
7.7 RESET
7.7.1 General presentation
This signal allows to make a Hardware RESET of the modem. In fact, this pin is used to force a RESET of
the modem, doing a low level during at least 10 ms.
This signal must be used only in case of emergency RESET.
This signal must be driven with an open collector assembly:
pin 14 (RESET) at 0, for the modem Reset,
pin 14 (RESET) at 1, for normal mode.
Pin description
Signal
Sub HD Connector
Pins number
I/O E/S Type Description
RESET 14 I/O SCHMITT Reset Modem
This signal must be used only in case of emergency RESET. A Software RESET is always
preferable to a Hardware RESET. It is strongly unadvised to execute this function whilst in
communication or dialog, without having first detached it from the network operator.
Using the RESET does not restore the factory parameters.
For more information concerning the Software RESET, see the document
"EG_EGM_CL_xxx_yy" of ERCO & GENER and refer to paragraph 5.10 to turn the device off