User guide

EG_GenPro2xe_1003_UG_005_UK Page 40 / 63
Descriptions and non-contractual illustrations in this document are given as an indication only.
ERCO&GENER reserves the right to make any modifications.
Dct_427_00
7.4 Output +3.8V
The tension available on the pin 13 of the 15-pin sub D HD is: see table below
Table: Conditions of use
Parameters Condition Min. Typ. Max. Unit
V
out
5.5 V +VDC 32V 3.8 Vdc
I
out
Max. 100 mA
When the battery option is present, the tension available on the pin 13 of the 15-pin sub D HD
is
Parameters Condition Min. Typ. Max. Unit
V
out
Without power supply * 2.8 4.2 Vdc
5.5 V +VDC 32V 4.4 4.5 Vdc
I
out
Max. 100 mA
* The min. 2.8 V is the limit of auto protection of the battery. From this moment, the
battery puts itself in protection, and the output tension becomes null.
When the battery is not connected, the output tension is 4.4V Vout 4.5 V as long as the
power supply +VDC is present