User guide

EG_GenPro2xe_1003_UG_005_UK Page 22 / 63
Descriptions and non-contractual illustrations in this document are given as an indication only.
ERCO&GENER reserves the right to make any modifications.
Dct_427_00
The modem is now ready.
There are different cases depending on the application or library installed inside the equipment:
- Without library: corresponds to the Boot_Loader.
- With EGM standard library.
- The application ERCO & GENER EasePro-01.
- The owner application..
5.1.3 Checking the communication with the modem
5.1.3.1 Without Library
The GenPro 2xe does not contain any library, it will return the menu of the Boot-Loader.
Connect the link RS232 between the DTE (the COM port) and the modem (DCE).
Set the RS232 port of the DTE as follows:
Bits per second : 115 200 bps,
Data Bits: 8,
Parity: None,
Stop Bits: 1,
Flow control: material.
Use a communication software like HyperTerminal ® of Windows.
Menu by default when there is no library inside the equipment (example of display)
Bootloader V2.27L UE GenPro 2xe ENF (HW0C rev C)
1 - Update application
2 - Erase objects
M - GSM direct access
A - Advanced
E – Exit
With this status, the led is off.
In the case where no communication can be established with the modem:
Check the RS232 connection between the DTE and the modem (DCE),
Check the configuration of the COM port of the DTE.