Technical data
11
B. SAFETY
B-1. SAFETY RULES
ATTENTION! Before starting the burner it is necessary to know in details all
regulations of the hereby manual. It is needed to keep all common rules for the
safety when working with heating-technical devices.
· The boiler premises where the equipment will be installed, must respond
to all the fire requirements according to the current standards and lows.
· The device should be placed a in way, so there will be enough space for
cleaning, removing the soot from the burner, the boiler and the draught pipes.
· The burner must be installed in the boiler outlet with the relevant isolation.
It must be joined up with nuts. Under one of the nuts there must be put a
SPECIAL T-FIGURE TIN DETAIL which is for pushing the limit switch,
INFORMING THAT THE BURNER IS INSTALLED. It is absolutely forbidden the
eliminating of this protection since it is directly connected to the fire safety.
· The contact between the burner and the boiler should be well tight in
order to prevent gas leaks in the service room.
· When installing the system, it should be in optimal horizontal position.
The hose should be straight and the connections should be tight.
· After connecting the burner to the boiler, the technician should connect
the burner to the electrical network as shown on the enclosed connection scheme.
ATTENTION! The connection must be done by a qualified electrical technician
and there must be paid high attention to the safety grounding of the device. The
connecting is shown in the present manual and also with special stickers to the
main cable.
· The auger transporter connects by a special plug and switch and it is
controlled by a special consistency (there are two plugs on the burner,
ATTENTION! THE DOWN PLUG CH IS CONSTANTLY UNDER PRESSURE
AND IS DESIGNED FOR INITIAL CHARGING OF THE AUGER, the other one
is for normal work. This is shown with stickers on the plug and on the pin-plug).
· The burner is designed ONLY FOR BURNING PELLETS FROM
WOODEN FRAGMENTS!