Specifications

p 9
Eraser Company Inc. • Syracuse, NY USA • Ph: 315-454-3237 • info@eraser.com • www.eraser.com • Fax 315-454-3090
+1. After inputting ‘1’ at the KIT SELECT screen,
the cursor is at the ‘SELECT BATCH:’ parameter of
the KIT EDIT screen (above). The Position Indicator
(see table below for Indicator denitions) displays
an “F”, meaning that this is the “rst” batch in this
kit. In addition, the Allowable Action Indicator (see
table below for Indicator denitions) displays an “A”,
meaning that a batch may be “added”.
POSITION INDICATOR – Located between INDEX
# and KIT #, on the rst (top) line.
SymbolDenition
F First batch in kit (index #0).
M Middle batch.
L Last batch (last index in kit, can be deleted or
changed).
N New index position (this status is temporary until
this index/batch is saved).
ALLOWABLE ACTION INDICATOR – Located after
Batch number, on the second line.
SymbolDenition
E - Edit - can change batch # at current index.
D - Delete - remove or change batch from current
index (only possible for the last index in the kit),
also implies an edit if it is necessary.
A - Add - add batch and index location to kit (batch
not yet selected for current INDEX).
To continue with the example outlined above, Batch
4 will be the rst batch to be run in this kit so it will
be entered at index 0. The operator presses the <4>
key, then the <ENTER> key, to enter Batch #4 as
Index #0 of the kit. The KIT EDIT screen displays:
INDEX #0 F KIT#1
SELECT BATCH: 4 D
LENGTH 6.0
QUANTITY 1
The batch number, length and quantity are displayed
for the entered batch (in this example, Batch 4) and
the Allowable Action Indicator (see table above)
changes to a “D”, meaning that this batch number
can be “deleted” from the kit. When the operator is
satised he/she has chosen the correct batch, press
the <+> or <ENTER> key to move to the next index,
and to enter the next batch in the kit’s sequence.
The KIT EDIT screen displays:
INDEX #1 N KIT#1
SELECT BATCH: 0 A
LENGTH .0
QUANTITY 0
The second location is numbered INDEX #1 (the
counting for indexes starts at zero), the Position
Indicator displays an “N” (indicating a “new” index
position) and the Allowable Action Indicator displays
an “A”, meaning that a batch number can be “added”
to this location. The operator then presses the <5>
key, then the <ENTER> key to place Batch 5 into the
second sequence in this kit. The KIT EDIT screen
displays:
INDEX #1 L KIT#1
SELECT BATCH: 5 D
LENGTH 8.0
QUANTITY 3
The Position Indicator now displays an “L” (the “last”
batch in this kit so far) and the Allowable Action
Indicator displays a “D”, meaning that this batch
can be “deleted” from the kit. Only the last batch
in a kit may be deleted. When the “D” is displayed,
the operator can delete the batch from the kit by
pressing the <CUT> key. When the operator is
satised he/she has chosen the correct batch, press
the <+> or <ENTER> key to move to the next index,
and to enter the next batch in the kit’s sequence.
The KIT EDIT screen displays:
INDEX #2 N KIT#1
SELECT BATCH: 0 A
LENGTH .0
QUANTITY 0
The Position Indicator displays an “N” (indicating
a “new” index position) and the Allowable Action
Indicator displays an “A”, meaning that a batch can
be “added” to this location. To enter the last batch in
this example kit, the operator presses the <6> key
and then the <ENTER> key. The KIT EDIT screen
displays:
INDEX #2 L KIT#1
SELECT BATCH: 6 D
LENGTH 2.0
QUANTITY 1
MODEL WC601A AUTOMATIC WIRE & TUBING CUTTER