Standard Properties: The Standard tab contains options for the parameter file, host
connection, supply oscillator, and operating mode. Refer to the user’s manual for the target
device when setting properties.
Figure 48. Device Setup Box: Standard Tab
Table 11. Device Setup Box: Standard Properties
Group/Item Option Description
Parameter file
S
p
ecifies the
p
arameter file to be rewritten into the tar
g
et MCU’s flash memor
y
Note: parameter file data must not be revised because it is related to the
guarantee of rewrite data. The checksum function protects the parameter file. If
the checksum result indicates an error, the FPL3 does not accept the file.
PRM File
Read button
Opens a window for specifying a parameter file is displayed. Specify a desired
file then click
Open
Selects a channel from COM1 to COM256 for communication between the
DemoKit-LG2
b
oard an
d
host com
p
ute
r
Port list box
Ports also can be selected using the Device Manager, as explained in Section
5.3
,
“Confirmation of USB Driver Installation.”
Host
connection
Speed list box
Selects a communication rate for the selected communication channel:
9600 bps
19200 bps
38400 bps
115200 bps
For selectable communication rates
,
refer to the MCU user's manual.
Frequency box
Sets the clock frequency of the target system; operating frequency varies by
device
,
so alwa
y
s check device s
p
ecifications before settin
g
the fre
q
uenc
y
Specifies the division rate or multiplication rate of the target device. If the
target device has an on-chip PLL circuit, enter a division rate or multiplication
rate according to the user environment. The selectable division rate or
multi
p
lication rate differs de
p
endin
g
on the device
Supply
oscillator
Multiply rate
Before making a selection, check the specifications of the device used. If the
target device does not have an on-chip PLL circuit, select "1.0". On the initial
screen
,
the default settin
g
is dis
p
la
y
ed accordin
g
to the
p
arameter file.