Technical data

61
DCF OFF
- Touch “ON” to toggle between activating (ON) and deactivating (OFF) DCF-recep-
tion.
Activating/Deactivating daylight saving adjustment
- Select the “SYSTEM” menu then the DST option (via BEEP and DCF) and the fol-
lowing appears:
DST ON
- Touch “ON” to toggle between activating (ON) and deactivating (OFF) automatic
daylight saving adjustment.
Setting the data logger recording interval
The data logger recording interval denes the intervals at which the integrated data
logger is to log records. The shorter the selected intervals, the shorter the recording
time, which results in more detailed records. The longer the intervals, the longer the
possible recording time, which results in a lower resolution for the weather data. The
recording interval can also be set from the PC.
- Select the “SYSTEM” menu then the “INTERVAL option (via BEEP, DCF and DST)
and the following appears:
INTERVALL ENTER
- Touch “ENTER” and the following appears:
INTERVALL + 05 -
-Touch“+”or“-”tosettheintervaltime(OFF[dataloggero]orbetween5and
60 minutes). Below are a few examples of how the interval time and recording time
relate to one another.
Interval time Max. recording time
OFF no recording
5 minutes 10.4 days (250 hours)
10 minutes 20.8 days (500 hours)
30 minutes 62.5 days (1500 hours)
60 minutes 125 days (3000 hours)
ALTITUDE”, setting the height of the location above sea level
The location height is used to calculate the relative barometric pressure at sea level
compared to the absolute barometric pressure at the location. This relative value is
an important reference variable that is needed to correctly interpret weather reports
that are based on the relative barometric pressure.