Instructions

If the adapon run has been iniated prior to installing, please
press the control wheel briey and the motor reverses to the
“INS” posion. If an error message (F1, F2, F3) is displayed, the
motor similarly travels back to the “INSposion (see secon
25).
11. Seng the program for the week
For each day, up to 3 heang phases (7 change sengs) can be set sep-
arately. The programming is carried out for the selected days, where-
by temperature sengs have to be set for the enre period between
00:00 and 23:59.
The device is pre-programmed with a schedule for the week (see sec-
on 11.1). To set your own schedule, please follow the instrucons
below:
Press the Mode/Menu buon for at least 3 seconds. „PRO“ appears
in the display. Conrm by pressing the control wheel briey.
„DAY“ appears in the display. Rotate the control wheel to select
either a single day of the week, all weekdays, the weekend, or the
enre week.
Conrm by pressing the control wheel briey.
The rst switching me point is displayed (0:00), this can not be
changed.
Conrm by pressing the control wheel briey.
Now set the temperature which is desired from 0:00hrs.
Conrm by pressing the control wheel briey.
The next switching me point is displayed. You can adjust this by
rotang the control wheel.
N o w s e t th e te m p e r a t u r e w h i c h s h o u l d p r e v a i l f r o m t h e s e l e c t e d m e .
Repeat this procedure unl all the other desired temperatures for
the me period from 0:00 to 23:59 have been stored.
If all 7 switching me points have been allocated, 23:59 is displayed
as the nal switching point to be conrmed.
Bars for switching me periods for every second me interval
are shown in the display.
In auto mode, the temperature can be changed at any me using
the control wheel. The modied temperature will then remain
the same unl the next point at which the program changes.
11.1 Week program: Example
For each day of the week up to 3 heang phases (7 change sengs)
with individual temperature sengs can be saved with the radiator
thermostat.
Two heang phases from 6:00 to 9:00 and from 17:00 to 23:00 for all
weekdays alike are saved as factory sengs:
from 00:00 to 06:00 17.0 °C
from 06:00 to 09:00 21.0 °C
from 09:00 to 17:00 17.0 °C
from 17:00 to 23:00 21.0 °C
from 23:00 to 23:59 17.0 °C
In this example, bars are displayed only for the intervals 06:00
to 09:00 h and 17:00 to 23:00 h.
12. Display content in normal mode
Switching me periods, operang mode,
programmed temperature and week day are
displayed in normal mode.
The bars for switching me periods of the week
program will be displayed for every second
me interval (please see “11.1 Week program: Example”).
13. Boost funcon
The boost funcon makes use of human sensaons of heat. When ac-
vang the boost funcon, the heang valve is immediately opened
to 80 % for 5 minutes (factory seng). The heang of a room takes
longer than 5 minutes, but the heat given oby the radiator can be
felt immediately. If, for example, you arrive home earlier than usual or
you need some extra heat in the morning in the bathroom, the boost
funcon will help you to heat the room up quickly.
Press the control wheel briey to acvate the boost buon.
The remaining me for the funcon will be counted down in sec-
onds (“B299” to “B000”).
Aer these 5 minutes have elapsed, the device changes to the mode
which was previously acve (auto/manu) with the previously set
temperature.
The funcon can be deacvated prematurely at any me by press-
ing the control wheel again.
The boost funcon will not have an immediate eect if the ra-
diator is covered or concealed (e.g. by a sofa). The open-window
funcon is deacvated while the boost funcon is acve.
14. Seng the holiday funcon
If you want to maintain a xed temperature for a certain period, e.g.
during your holidays or a party, the holiday funcon can be used.
Briey press the Mode/Menu buon repeatedly, unl the suitcase
symbol ( ) appears in the display.
Change the me unl which the temperature shall remain with the
control wheel and conrm by pressing the control wheel briey.
Then set the date and conrm by pressing the control wheel briey.
Set the temperature and conrm by pressing the control wheel
briey. The display will ash to conrm.
The set temperature will remain unl the set end me. Aerwards,
the radiator thermostat will switch back to auto mode.
15. Comfort and eco temperature
The comfort and eco temperature buon ( ) makes switching be-
tween comfort and eco temperature simple and user friendly. The
factory seng for the comfort temperature is 21.0 °C and the eco
temperature 17.0 °C. They can be adjusted as follows:
Press and hold the comfort/eco buon ( ) for at least 3 seconds.
The sun symbol ( ) and the currently stored comfort temperature
appear in the display.
Change the temperature with the control wheel and conrm by
pressing the control wheel briey.
The moon symbol ( ) and the currently stored eco temperature
appear in the display.
Change the temperature with the control wheel and conrm by
pressing the control wheel briey.
Even in auto mode, the temperature can be changed at any me using
the buon. It will then remain the same unl the next point at which
the program changes.
16. Display of valve posion
You can request the current posion of the valve. To do this, proceed
as follows:
Press the Mode/Menu buon for at least 3 seconds.
Choose the menu item “POS” by rotang the control wheel.
Conrm by pressing the control wheel briey.
The display will show the current posion of the valve drive.
17. Child safeguard/operang lock
The operaon of the device can be locked.
To acvate/deacvate the operang lock, press the Mode/Menu
and buon at the same me.
Aer it has been successfully acvated, LOCappears in the display.
To deacvate the operang lock, press both buons again.
18. Acvate heang pause (baery saving)
Baery life can be prolonged by switching the heang o in summer.
To achieve this, the valve is opened fully. The de-calcicaon protec-
on connues to run.
To acvate the heang pause, proceed as follows:
Turn the control wheel in manu mode (manu) to the right unl ON
appears in the display.
To end it, exit the manu mode (manu) or turn the selector dial to
the le.
19. Set frost protecon mode
If a room is not to be heated, the valve can be closed.
Turn the control wheel in manu mode (manu) to the le unl “OFF”
appears in the display.
The valve is only opened if there is a risk of frost. The de-calcicaon
protecon connues to run.
To end it, exit the manu mode (manu) or turn the control wheel to
the right.
20. Switch between summer and winter me
The automac switching between summer and winter (and vice versa)
on the agreed European date occures in the early hours of the Sunday.
The automac switching is acvated in the factory sengs. It can be
manually deacvated as below:
Press the Mode/Menu buon for at least 3 seconds.
Choose the menu item “DST” with the control wheel.
Conrm by pressing the control wheel briey.
Set the opon “OFF” to deacvate automac switching or set the
opon ON to ac vate a u t o m a c s w i t c h i n g w i t h the control wheel.
Conrm by pressing the control wheel briey.
21. Open-window funcon
With a rapidly reducing temperature, the radiator thermostat automat-
ically detects that a room is being venlated. In order to save heang
costs, the temperature is then regulated down for a certain period of
me (15 minutes, set at the factory). Whilst this funcon is acve, the
open-window symbol ( ) appears on the display.
To congure the funcon, proceed as follows:
Press the Mode/Menu buon for at least 3 seconds.
Select the menu item “AER” with the control wheel and conrm by
pressing the control wheel briey.
The temperature and me can be set with the control wheel. The
funcon can be deacvated by selecng “0” for the me.
22. Set oset temperature
As the temperature is measured at the radiator, the temperature dis-
tribuon can vary throughout a room. To adjust this, a temperature
oset of up to ±3.5 °C can be set. If a nominal temperature of e.g. 20
°C is set but the room presents with only 18 °C, an oset of -2.0 °C
needs to be set.
To set the oset temperature proceed as follows:
Press the Mode/Menu buon for at least 3 seconds.
Select the menu item “TOF” with the control wheel and conrm by
pressing the control wheel briey.
Turn the control wheel for as long as necessary unl the desired
temperature oset appears.
Conrm by pressing the control wheel briey.
23. Restoring the factory sengs
The factory sengs of the radiator thermostat can be restored man-
ually. If you do this, you will lose all your sengs.
To do this, proceed as follows:
Press the Mode/Menu buon for at least 3 seconds.
Select the menu item “RES” with the control wheel and conrm by
pressing the control wheel briey.
“CFM” then appears in the display.
Conrm by pressing the control wheel briey.
24. Intended use
The programmable radiator thermostat is used to control a conven-
onal thermostac radiator valve. Only operate the device in inside
rooms and avoid the inuence of moisture, dust and sunlight or ex-
ternal heat radiaon.
Using the radiator thermostat for any purpose other than that de-
scribed in this operang manual does not fall within the scope of in-
tended use and shall invalidate any warranty or liability. This also ap-
plies to any conversion or modicaon work. The device is intended
for private use only.
25. Troubleshoong and maintenance
Error code on
the display
Problem Soluon
Baery symbol
( )
Baery output too
low
Replace baeries
F1
Valve drive slug-
gish
Check installaon,
check the heang valve
F2
Adjustment range
too wide
Check the fastening of the ra-
diator thermostat
F3
Adjustment range
too small
Check the heang valve
The radiator thermostat performs a roune descaling run once
a week on Saturday at 12:00 to protect against calcicaon of
the valve. During this “CAL” appears in the display.
26. Technical characteriscs
Device short descripon: CC-RT-M-EQ
Supply voltage: 2x 1.5 V LR6/Mignon/AA
Current consumpon: 100 mA (max.)
Baery life: 3 years (typ.)
Degree of protecon: IP20
Degree of polluon: 2
Ambient temperature: 0 to 50 °C
Surface temperature: 90 °C (at the radiator)
LCD: 85 segments
Connecon: M30 x 1.5 mm
Method of operaon: Type 1
Linear travel: 4.3 mm
Dimensions (W x H x D): 58 x 63 x 122 mm
Weight: 176 g (incl. baeries)
Subject to technical changes.
Bevollmächgter des Herstellers:
Manufacturer’s authorised representave:
eQ-3 AG
Maiburger Straße 29
26789 Leer / GERMANY
www.eQ-3.de