8 Maintenance and cleaning
To ensure operational liability of the smoke alarm, the device has to be
maintained at least once a month. To do this, proceed as follows:
• Wipe the housing with a slightly damp cloth if necessary.
• Shortly press the operating button to perform a function test.
• If the alarm sound is triggered 3 times, the LED ashes red and the
escape light ashes at the same time, the smoke alarm is working
correctly.
• If no alarm sound is triggered or no visual signal can be detected, the
device is defective and has to be replaced.
9 Battery life
The smoke alarm is powered by a permanently sealed lithium battery
with a typical lifetime of 10 years. Batteries cannot be replaced.
The battery life of typically 10 years can only be enabled under
the following conditions:
• A max. number of 52 function tests and one alarm for 60 sec. may be
performed per year.
• The operating ambient temperature of +5° to +30°C has to be main-
tained.