Switch Type is another configuration parameter that depends on the Service Provider when acting in the User mode and the private PBX
capabilities when acting in the Network mode.
The Generate Progress Tone to PSTN/PBX drop-down list contains the options for sending progress (ring-back) tone to callers from the
PSTN/PBX. The following options are available in the list:
• None configures the system to send ALERT messages without the Progress Indicator information element (IE).
• Unconditional configures the system to send ALERT/PROGRESS messages with the Progress Indicator IE. With this option, the system will
send its own progress tone.
• Conditional configures the system to send ALERT/PROGRESS messages with Progress Indicator IE. With this option, the system will send its
own progress tone only if there is no early media (180/183 with SDP) from the called party.
Incoming Called Digits Size text field indicates the number of received digits (in a range from 0 to 255) required to establish a call. When field has 0
value, system uses either timeout defined in the T302 field or the Sending Complete Information element messages to establish a call.
Independent on the value in this field, Sending Complete Information element and pound sign always cause the call establishment.
DID Service:
• Disable DID Service disables the DID Service.
• Enable DID Service enables the DID Service. The CCS DID Service button leads to the Trunk CCS DID Service page where the CCS DID
number(s) may be configured.
The CCS DID Service page is used for mapping a group of DID numbers to the certain destinations on the Quadro.
To begin managing DID numbers, you must do the following:
In the Start DID Number and End DID Number text fields enter a
range of DID numbers.
The Start DID Number field must indicate a shorter number than
the End DID number
field. Otherwise the following error message
appears: "End DID number should be greater than Start DID
number."
Select the destination from the Incoming/Outg
oing Call
To/From drop-down list where the incoming/outgoing call
addressed to the certain DID numbers range will be routed.
The DID number can be assigned to the Quadro’s extensions, to
the Auto Attendant, or to the routing agent.
Choosing the Routing with inbound destination number
selection will automatically use the initially dialed number to
connect the destination without any additional dialing.
The following functional buttons are available on this page:
• Add is used to add the range of DID numbers. Once the DID
numbers have been added, you will see the extensions and
their assigned DID numbers in the table below.
For example, if you have inserted 1000 in the Start DID
number text field and 1003 in the End DID number text
field, then DID numbers 1000 1001, 1002 and 1003 will be
added to the table.
• Delete is used to delete the DID numbers from the table with
the selected range in the Start DID Number and End DID
Number fields.
• Delete All is used to delete all DID numbers from the table at
once.
Fig. II-202: Trunk 1 CCS DID Service page
Please Note: You can add DID numbers of up to 20 digits long and up to 500 DID numbers can be specified.
To assign DID numbers to a consecutive extensions, choose an extension from the Incoming/Outgoing Call To/From drop-down list and select the
Generate from Selected Extension Number checkbox. This will automatically assign DID numbers to a consecutive extensions starting from the
selected extension.
Modify the fields in the table you wish to update and click the Save button.
Selecting the Use Default outgoing Caller ID allows you to overwrite the source caller information with the one specified in the Default outgoing
Caller ID field when placing outgoing calls toward the CO, if the default caller ID does not match one(s) listed in the Incoming/Outgoing Call
To/From field.
The Default outgoing Caller ID field requires the caller ID for the outgoing calls from the Quadro through the E1/T1 trunk. If this checkbox is
enabled but no value is defined in the Default outgoing Caller ID, empty caller information will be sent to the CO. If this checkbox is disabled and
the default caller ID does not match one(s) listed in the Incoming/Outgoing Call To/From field, source caller information will be forwarded to the
CO.
The Generate Progress tone on IP checkbox selection will generate the progress tone to IP (H.323 or SIP).