User manual
  X K 3 1 9 0C 602   
printer) 
  There is only English format for parameter print, the explanation is as follows 
Content of print  Explanation 
C602 Ver1.00  Instrument type and software version No. 
Max=: 020.000kg  Max. capacity 20kg 
e= : 01  Scale interval (effective bit) 1 
Dp : 03  Decimals 3 
0_AD: 00262121  AD code of calibrated zero point 
0Point: 000.000kg  Current zero point (corresponding to calibrated zero 
point)   
R : 00067106  Standard rate 
Line: 000.000%FS  Non-linear modification value 
COMM:111110 
Communication setting, corresponding toSET 1
parameter 1 
0_SET 141 
Zero-settingrelative toSET 1parameter 2 
Flt : 1222 
Filtration  setting,  corresponding  to  SET    1 
parameter 3 
Addr: 01 
Communication addresscorresponding toSET 1
parameter 4 
Buad: 44 
Baud ratecorresponding to SET 1parameter 5
Mode: 22 
Communication mode, corresponding toSET 1
parameter 6 
Prnt: 1 
Printer type, corresponding toSET 1parameter 7
PL : 00 
Print language, corresponding toSET 1parameter 
8 
AutoP 12 
Automatic  print,  corresponding  to  SET    1 
parameter 9 
Aout_W 020.000kg  Full  measurement  range  weight  of  analog  output, 
corresponding toSET 1parameter 10 
Aout_0 00000  Zero DA code of analog output, corresponding to 
SET 1parameter 11 
Aout_F 65070  Zero DA code of analog output, corresponding to 
SET 1parameter 12 
Type: 212 
Equipment  type,  corresponding  to  SET    1 
parameter 13 
Disp: 04 
Display  content,  corresponding  to  SET    1 
parameter 17 
Light: 5 
Display  brightness,  corresponding  to SET    1
parameter 16 
F.3.1 Print of Working Parameters of Quantitative Scale 