User manual
  X K 3 1 9 0C 602   
Note 4 of Table E-2: NN=00: read accumulated data, NN=01: read all stored data. 
Codes of accumulated data of quantitative scale: Tc total times; Tw total weight. Codes of accumulated data 
of batching scale: Tc  total  times; Tw total weight;  1C~5C total times of  channel 1 ~  channel 5; 1W~5W total 
weight of channel 1~ channel 5. 
Format of saved data output: 
02H, address, command (S), sequence No. (five bytes), space (1 byte), [time (yy/mm/dd/hh:mm:ss) (if there 
is time data only whenSET—1parameter 9B = 2)], weight (7bytes), 0DH, 0AH, 03H. 
If there is no data or the data is sent out, return to original command. 
Note 5 of Table E-2: Parameter code is same as Note 2. Two ends of data character string are separated by a 
space respectively, parameter length is limited within 8 characters, parameter value should be in effective range 
specified in the specifications, or unexpected problem may occur. After all data requiring modification are sent, at 
last one write command will be sent, which is the command with parameter code WR and without parameter value. 
Note 6 of Table E-2: parameter code is same as Note 3, and parameter limitation is same as Note 5. After all 
data requiring  modification are  sent, at  last one write  command  will  be sent,  which  is the  command with 
parameter code WR and without parameter value. 
Note 7 of Table E-2: the parameter is 1 ASCII character 0, 1 or ?, 1 represents entering remote control state, 
0 represents exiting  remote  control state, ? represents  inquiring  remote control state.  After PC has  sent the 
command of converting to remote control state, if C602 is in stop state, remote control state will be entered; if 
C602 is in operation state, this command will be omitted; the returned command parameter is 0. 
Note 8 of Table E-2: See Table E-6 for the meaning of NN parameter. Parameter value is represented by 3 
digits of integer, indicating 8 digits of binary data. 8 digits of binary data of input and output signal state are 
relevant to all signals. See E-7 for the content of signal light state.   
Table E-6 Definition of Parameter of Signal Reading State 
Parameter code  Definition 
ST  Instrument signal light state 
I0  Basic input signal state 
I1  Input signal state of the first IO extended module 
I2  Input signal state of the second IO extended module 
I3  Input signal state of the third IO extended module 
I4  Input signal state of the fourth IO extended module 
O0  Basic output signal state 
O1  Output signal state of the first IO extended module 
O2  Output signal state of the second IO extended module 
O3  Output signal state of the third IO extended module 
O4  Output signal state of the fourth IO extended module 
Table E-7 Definition of Character for Signal Light State 
Bit  B7  B6  B5  B4  B3  B2  B1  B0 
Definition  Remote 
control 
Net 
weight 
Zero 
point 
Stable  Weighing  Communication  Stop  Run 
Note 9 of Table E-2: this command is only effective in remote control state, for write output signal. C602 can 
execute this command at once after receiving it, and change corresponding IO port output state. Parameter code 










