User manual
  X K 3 1 9 0C 602   
zero) 
AQNL 000.000 1C  Non-linear modification value 0 
AQAD 2 27  AD transfer speed 2 60cps 
AQFL 2 28  Filtration strength 2 
AQFm 1 0A  Filtration method 1 
AQSt 2 05  Stable judgment 2 
AQ0T 1 45  Zero tracking range 10.5e 
AQ0S 1 42  Zero setting range 1 
AQ0I 4 5D  Initial zero setting range 420% 
AQEI 1 2D  Initial zero setting switch 1on 
AQUt 2 03  Weight unit 2kg 
Note 3 of Table E-2: Codes of working parameter: MG instrument working mode; Lt display illumination; 
ZX main display content; FX auxiliary display content; Ad instrument communication address; Pr printer type; PL 
printer language; 1C working mode of serial port 1; 2C working mode of serial port 2; 1B baud rate of serial port 1; 
2 B serial port 2 baud rate; Ao weight relevant to full measuring range of analog output; FA DA code of full 
measuring range of analog output;  0A  DA  code  of  analog output  zero;  DA definition  of analog  output;  EA 
switch of analog output; 1E switch of serial port 1; 2E switch of serial port 2; EP switch of printer; AP automatic 
printing  switch; AM automatic  storage  ;  EB  large  screen switch; Pf parameters  number;  0Z  zero  area;  T0~T7 
timing  constant  T0~T7;  P1~P8  batching  value,  refer  to  Table  E-4.  CY  cycling  times:  Tq  switch  of  lead 
modification; Cc out-of-tolerance treatment switch; Db gradual feed switch; Ff peak value holding switch. Refer to 
Table E-5 for returned data and explanation 
Table E-4 Meanings of Working Parameter Codes P1~P8 
Code  Quantitative scale  Catchweigher 
P1  A1 batching of material 1  A upper limit of channel 1 
P2  B1 quick feed lead of material 1  B upper limit of channel 2 
P3  C1 slow feed lead of material 1  C upper limit of channel 3 
P4  D1 allowance of material 1  D upper limit of channel 4 
P5  A2 batching of material 2  —— 
P6  B2 quick feed lead of material 2  —— 
P7  C2 slow feed lead of material 2  —— 
P8  D2 allowance of material 2  —— 
Table E-5 Explanation of Returned Setting Parameter Data of Instrument 
Returned data of 
instrument 
Explanation 
ARMG 2 2B  Equipment type 2: automatic control of catchweigher 
ARLt 5 1E  Display illumination 5 
ARZX 0 21  Main display content 0: weight 
ARFX 4 39  Auxiliary  display  content  4:  work  step  (operation 
state)/time (non operation state) 
ARAd 01 37  Communication address 01 