User manual
  X K 3 1 9 0C 602   
Send  by 
instrument 
Pause/Continue 
02H Addr K XH XL 03H  02H AK0A  03H 
the  instrument  enters 
into  pause  or  running 
state 
Send  by 
PC 
Accumulate 
02H Addr L XH XL 03H  02H AL0D 03H 
L 
Send  by 
instrument 
Accumulate 
02H Addr L XH XL 03H  02H AL0D 03H 
Send  by 
PC 
Print 
02H  Addr  M  XH  XL 
03H 
02H AM0C 03H 
M 
Send  by 
instrument 
Print 
02H  Addr  M  XH  XL 
03H 
02H AM0C 03H 
Send  by 
PC 
Print 
accumulation 
02H Addr N XH XL 03H  02H AN0F 03H 
N 
Send  by 
instrument 
Print 
accumulation 
02H Addr N XH XL 03H  02H AN0F 03H 
Send  by 
PC 
Print working 
parameter 
02H Addr O XH XL 03H  02H AO0E 03H 
O 
Send  by 
instrument 
Print working 
parameter 
02H Addr O XH XL 03H  02H AO0E 03H 
Send  by 
PC 
Print calibration 
parameter 
02H Addr P XH XL 03H  02H AP11 03H 
P 
Send  by 
instrument 
Print calibration 
parameter 
02H Addr P XH XL 03H  02H AP11 03H 
Send  by 
PC 
Read calibration 
parameter 
02H  Addr  Q    XH  XL 
03H 
02H AQ10 03H 
Q 
Send  by 
instrument 
Send calibration 
parameter 
02H Addr Q NN ****** 
XH XL 03H 
…… 
The  instrument returns 
to  all  calibration 
parameters.  See  note  2 
for details. 
Send  by 
PC 
Read working 
parameter 
02H Addr R XH XL 
03H 
02H AR13 03H 
R 
Send  by 
instrument 
Send working 
parameter 
02H  Addr    R  NN 
****** XH XL 03 
…… 
The  instrument returns 
to  all  calibration 
parameters.  See  note  3 
for details. 
Send  by 
PC 
Read saving 
record 
02H Addr S NN  XH 
XL   03H 
02H AS0012 03H 
See note 4 for details. 
S 
Send  by 
instrument 
Send saving 
record 
02H  Addr    S  NN 
****** XH XL 03H 
…… 
The  instrument returns 
to accumulation data or 
record all data. 
See note 4 for details 